Products

The automated nucleic acid extraction and purification system performs sample preparation before nucleic acid testing.
It automatically uncaps sample tubes, reads barcodes, aspirates samples, tightens caps, scans 96-well-plate barcodes, dispenses liquids, adds proteinase K, and performs nucleic acid extraction, washing, purification, elution, and magnetic-bead removal.
The process runs in a clean negative-pressure environment that separates operators from potentially hazardous specimens, reducing infection and environmental-contamination risks.
Automation also reduces laboratory staff workload and errors associated with fatigue.
Model:BQ-9800
Service Hotline+86-0571-85236562(Currently available in Chinese only)
Product Categories
| Sample processing volume | 1-1000μL |
|---|---|
| Number of samples | 96 samples |
| Magnetic-bead collection efficiency | 98% |
| Extraction efficiency | 99.99% |
| Sample processing time | 40–50 minutes |
| Instrument type | Magnetic-Bead Nucleic Acid Extractor |
| Application Areas | Healthcare, food and agricultural products, chemicals, biotechnology, pharmaceuticals and biopharmaceuticals |
| Automation level | Automated Nucleic Acid Extractor |
Automated Nucleic Acid Extraction and Purification System Specifications. | Description |
Sample types | Throat swabs, nasal swabs, anal swabs, whole blood, serum, plasma, secretions, exfoliated cells, tissue, urine, feces, and other samples. |
Pipetting range | 5–1000 µL, optional configuration. |
Pipetting precision | 1 µL-20 µL≤5%;10 µL-200 µL≤2%;50 µL-1000 µL≤1% |
Pipetting accuracy | 1 µL-20 µL≤±10%;10 µL-200 µL≤±5%;50 µL-1000 µL≤±2% |
Method | Magnetic-bead extraction |
Extraction principle | Magnetic rods with disposable tip combs |
Instrument functions | Integrates automated aliquoting, nucleic acid extraction, purification, and magnetic-bead removal for clinical specimens in a single workflow. |
Magnetic-bead recovery rate | ≥98% |
Parameter | Description |
Sample throughput | Two-level workstation: uncapping and aliquoting of 1–96 samples; nucleic acid extraction and purification of 96 samples. |
Processing speed | Aliquoting: 96 samples, including barcode scanning, in 22 minutes. Extraction and purification: automatic reagent addition according to the selected kit; extraction, purification, elution, and magnetic-bead removal for 96 samples in 25–35 min. |
Compatible sample tubes | Supports various primary sample tubes, including centrifuge tubes, cryovials, viral sampling tubes, and blood collection tubes. |
Pipetting channels | 1 independent liquid-dispensing channel. |
Magnetic tip comb | 96-position magnetic tip comb |
Contamination control | Built-in UV lamp and HEPA-filtered negative-pressure system. |
Mixing modes | Multiple modes with adjustable speeds. |
Parameter | Description |
Incubation temperature | Adjustable from room temperature to 100 °C, with overtemperature protection. |
Dimensions | Length × width × height: 1000 mm × 625 mm × 905 mm. |
Control and display | Fully automated control through a touchscreen and an all-in-one Windows computer, with 500 GB of program storage and selectable extraction protocols. |
Power requirements | AC220 V;50 Hz |
Weight | 100 kg |
Power consumption | 1100 W |
Operating environment | Temperature: 0–40 °C; humidity: <80%. |
Automated Nucleic Acid Extraction and Purification System Applications: hospital laboratories, disease-control centers, independent medical testing laboratories, mobile PCR laboratories, and biomedical companies.